PolyPrime is a low viscosity 100% solids deep penetrating, fast drying concrete primer. PolyPrime utilizes unique chemistries for a technology that gives rapid drying times even in adverse weather conditions (cold/damp or high humidity). PolyPrime’s technology actively displaces absorbed water from saturated concrete, thereby enhancing the surface strength of the concrete to tensile load and the adhesion of a subsequently applied topcoat.
PolyPrime is 100% solids and can be applied to the desired coverage weight in just one application, enhancing productivity and economy of use. PolyPrime also complies with the strictest state and federal VOC regulations and being solvent free, and is not classified as flammable.

Advantages

Limitations

Not recommended for:
Priming ferrous and non-ferrous metals.

Health & Safety

Consult product MSDS supplied separately.

Shelf Life & Storage

The product has a shelf life of six months when stored in the original unopened containers and not subject to temperatures below 70ºF and above 130ºF.

Product Codes

4500-00A31 PolyPrime - ISO
4500-00B31 PolyPrime RESIN CLEAR
(other colors available to minimum order quantity)

 

PHYSICAL PROPERTIES

RESIN Viscosity 250-500 cP @77ºF
ISO Viscosity 20-50 cP @77ºF
Mixed 100-200 cP @77ºF

 

Mixed Ratio*
By Volume 1 part ISO : 1 part RESIN
By weight 1.229 part ISO : 1 part RESIN
*Mix for 5 minutes or until solution clears prior to application.
Usable Pot Life: 2 hours
Tack free: 50 min
Time to recoat: 2 hours

 

Coverage Rate
Theoretical
1604 sq ft / gal / mil
Recommended 160.4 sq ft / gal @ 10 mil wft

 

Adhesion1 ASTM D4541
Concrete, dry (psi)

with PolyPrime 900 – 1000
no primer 350 - 450
Concrete, wet2 (psi) with PolyPrime 400 - 450
no primer 0
1PolyPrime applied at recommended coverage weight and top coated with PolySpray HE800.