High Temp HydraWrap® System

View More HydraWrap Products

High Temp HydraWrap® System - The High Temp HydraWrap® system is designed to provide a structural repair that will withstand elevated temperatures with minimal post-cure.

Acrobat Reader download/view pdf

High Temp HydraWrap® System
Advantages
Properties
Performance Data
Substrate Preparation
Performance Data
Installation Procedure
Note
Ordering Information

 

HYDRATECH HIGH TEMP HYDRAWRAP® SYSTEM

 

ADVANTAGES

The High Temp HydraWrap® system is a performance driven product that provides a chemical and corrosion resistant structural repair for infrastructure and the interior or exterior of pipe. The High Temp HydraWrap® system is backed by our engineering staff that services each application with assessment and technical support. The High Temp HydraWrap® system offers a low cost, long term solution to the most challenging demands of the industry.

 

PROPERTIES

  Primer Wet-Out
Color Steel Green Clear
Working Life –200ºF (93ºC) 60 minutes 60 minutes
Dry Times – 68ºF (20ºC) 24 Hours 24 Hours
% Vol Solids (ASTM 2369) 100 100
Shore D Hardness (ASTM D2240) 75 80
Mix Ratio - Pre-measured 1:1
Flash Point - > 200ºF (93ºC)
Storage Life - Twelve months when stored in original sealed containers, between 50-77ºF (10-25ºC)

 

PERFORMANCE DATA

Composite System
(two ply bidirectional)
Hoop
200C
Hoop
300C
Axial
300C
Tensile Strength
ASTM D3039 (ksi)
41.08 88.3 13.79
Tensile Modulus
ASTM D3039 (msi)
4.48 8.44 2.32
% Elongation
ASTM D3039
0.95 1.03 0.68
Flexural Strength
ASTM D790 (ksi)
64.4 106 19
Flexural Modulus
ASTM D-790 (msi)
3.16 4.18 0.98
CTE
ASTM E831 (x10-6/°F)
  16.8  
Maximum Operating Temperature (°F) 350 350 350
Conforms to DOT regulations • PCC-2 Art 4.1, 4.2 • ASME B31.1•.3•.4•.8 • API 570 • ISO15649 • ISO13623 • ACI  440.2R08
For details regarding the testing associated with the provided data refer to the HydraWrap Testing and Design Sheet.

 

SUBSTRATE PREPARATION

Substrate preparation dictates the adhesion performance of any coatings system. A properly prepped surface will ensure maximum life and performance of the system.

Concrete: NACE No.6*/SSPC-SP13*
Steel: NACE No.2* / SSPC-SP 10*
NACE No.3 / SSPC-SP 6
NACE No.5 / SSPC-SP 12
*indicates recommended method

 

PERFORMANCE DATA

CHEMICAL RESISTANCE ASTM D543 (30 day immersion)

Water No Effect
Sodium Hydroxide 5% No Effect
Ammonium Hydroxide 5% No Effect
Sodium Hypochlorite (bleach) No Effect
Ferric Chloride 1% No Effect
Sulfuric Acid 98% No Effect
Nitric Acid 1% No Effect
Detergent Solution No Effect
Gasoline No Effect
Toluene No Effect



ADHESION ASTM D4541 (24Hr cure)

Cold Rolled Steel >2,000 psi
Hot Rolled Steel >2,000 psi
Cast Iron >2,000 psi
304 Stainless Steel >2,000 psi
316 Stainless Steel >2,000 psi
Concrete Concrete Failure


APPLICATION REQUIREMENTS

Minimum Application Temp. 40ºF (4.4ºC)
Maximum Relative Humidity 85%
Substrate Temperature 5ºF (3ºC) above dew point
Thinning Do not thin
Cleaning Fluid Universal Equipment Cleaner
Note To aid application at low temperatures, both components should be warmed to 60-68ºF (15.5-20ºC) prior to mixing.

 

INSTALLATION PROCEDURE

For details regarding application refer to the HydraWrap Installation Procedure

 

NOTE

The High Temp HydraWrap® System is intended for short-term repairs in critical applications and some long-term applications. The High Temp HydraWrap® system is not intended for applications with exposure to strong acids, organic acids, strong solvents (MEK, Acetone, Alcohol) or temperatures exceeding 350°F. To be applied by certified personnel only. See MSDS for safety information.

  Unit Size Coverage
PRIMER Pt
Qt
Hg
4.5 sqft
9 sqft
23.5 sqft
WET-OUT Pt
Qt
4 sqft of fabric
8 sqft of fabric
(Primer coverage based on 32mil film build. Wet-Out coverage based on 99.36g/sqft of 300C fabric.)


ORDER INFORMATION

Part No. for standard kits consist of: System Code - Pipe Size - Pipe Style
ex. SH-12-W (STD HydraWrap for 12” Weld Repair)

System Code

Pipe Size

Pipe Style

SH – Standard HydraWrap 4 – will wrap up to one 4” pipe 12 – will wrap up to one 12” pipe W – Weld
HH – High Temp HydraWrap 6 – will wrap up to one 6” pipe 16 – will wrap up to one 16” pipe E – Elbow
AH – Acid Resistant HydraWrap 8 – will wrap up to one 8” pipe 18 – will wrap up to one 18” pipe T – Tee
PH – Potable Water HydraWrap 10 – will wrap up to one 10” pipe 24 – will wrap up to one 24” pipe SS –Strait Spiral
Custom kits are supplied to accommodate nearly any installation